Measure the depth of your current insulation.
Insulatiion required for a hot roof.
Typically a gap will have to be left for ventilation because this is a cold area.
Browse product options or contact your local insulfoam rep to help you quickly pick the best products to simplify your building envelope needs and fit your project budget all with one supplier.
Look for water stains on the roof sheathing or damp or moldy spots on attic joists and existing insulation as a clue to where leaks might be.
Calculate additional insulation needed.
Senior engineer manager at icynene john broniek makes the case for the unvented attic assembly and why insulating the underside of the roof makes sense.
Box out light fixtures.
Measure the area needing insulation.
If you have been considering a new roof installation looking into adding insulation to your home or are planning to build a new house you may have heard people talk about hot roof and cold roof systems.
Water is insulation s enemy.
Iecc 2015 requirements by climate zone 3.
If your current insulation is only 5 inches deep you ll need to add seven inches of insulation to achieve the 12 inch r 38 rating.
Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces.
The quest for greater energy efficiency in buildings has led to increasing interest and need for insulation improvements in hvac equipment more airtight construction new materials and assemblies.
However you may not be familiar with these concepts particularly what they mean and the pros and cons of each.
The benefits of a conditioned attic.
While some try to do this with fiberglass or cellulose their efforts are for naught and quite simply it is not allowed by any legitimate building code out there.
R value is a measure of insulation s ability to resist heat traveling through it.
Where the design of the roof ceiling assembly does not allow sufficient space for the required insulation such as cathedral ceilings the minimum required insulation for such roof ceiling assemblies shall be r 30.
Minimum insulation r value requirements non residential above roof deck.
Pa302 2 ceilings without attic spaces n1102 2 2 r402 2 2.
The table below shows what levels of insulation are cost effective for different climates and locations in the home.
The higher the r value the better the thermal performance of the insulation.
A hot roof is one where there is no ventilation required as the insulation is directly attached to the roof sheathing.
R 38 is the industry standard and the minimum thickness for r 38 is 12 inches.
Insulation level are specified by r value.