Lightning has caused many house fires that have flexible gas lines.
Is gas piping supposed to be labeled in attic.
Flexible gas lines are safe so long as you have little lightning.
Not as durable as traditional black iron.
Separate piping of adequate capacity shall be provided.
Often this is done by attaching the gas piping to the supply water piping assuming it is grounded frequently near the water heater.
The marking shall not be required on pipe located in the same room as the.
I say might because of pipe sizing issues.
I don t know if it matters but our winters rarely get below 25f but summers hover in upper 90s for jul aug.
A flexible gas line is made from thin wall stainless steel.
The marking shall be spaced at intervals not exceeding 5 feet 1524 mm.
Underground gas piping shall be installed with approved clearance from other underground structures to avoid contact therewith to allow maintenance and to protect against damage from proximity to other structures in addition underground plastic piping shall be installed with approved clearance or shall be insulated from sources of heat so as to prevent the heat from impairing the.
The yellow color is utilized to help identify the piping as gas line around 2005 the first black jacketed csst product was introduced.
Hi okfarmer what you propose might be acceptable according to the nfpa fuel gas code which is ineffect in virtually every jurisdiction that has an approved code.
Bonding the gas piping to the electrical grounding system is a requirement however in many jurisdictions.
A 1 2 line is probably adequate for a clothes dryer but i would need to know the total btu load on the main and the distance to the farthest fixture from the meter.
What was required per the federal lawsuit gas line schematic bond to the gas the manifold and any accessible exhaust thus making everything the same electrical potential and all the charge will run of the wiring eliminating any static charge on the gas piping.
The problem with the piping is that it is so thin that it does not carry a ground.
For other than steelpipe exposed piping shall be identified by a yellow label marked gas in black let ters.
To prevent an electrical potential buildup within the gas piping that could lead to arcing which might.
It s not durable like traditional black iron pipe.
The black jacket signifies a protective jacket design which provides a level of lightening arc protection to the csst tubing underneath.
Would like to assess the feasibility safety of running an lp gas line from a tank outside the home into the attic dropping down to the bay currently holding our electric range stove.